Mass Flowmeter Coriolis TMU/UMC-4
Wide measuring span
Measuring range: 0 - 60 kg/h ... 0 - 2200 t/h water
Connection: flange DN10 - DN400, ANSI ½ ... 16"
JIS, NPT, special according customers specification
Material:
stainless steel (1.4571 or 1.4404), Hastelloy® C-22
pmax: PN40 (higher on request)
Temperature range: -40 ... +260°C
Accuracy:
±0.1 (0.15) % of reading ±zero point-stability liquids
±0.5 % of reading ±zero point-stability gases
±0,005 g/cm³ with calibration density
±0,002(1) g/cm³ with special calibration density
±0,2% of reading ±zero-point-stability volume
Transmitter:
Analog / pulse output, digital display,
Hart®, Profibus® PA, ATEX, FM, FMC, NEPSI

Datasheet
Approvals
Description
The Kobold Mass Flow Meter model TMU utilizes the Coriolis principle of operation to measure mass flow. Density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters. The TMU Series is available with a direct mounted transmitter or in a remote mounted configuration.
The unit can be used to meter nearly all liquid or gaseous media and was especially designed to operate in many standard applications. It is applied in many different industrial branches. The TMU Series is also used for precise dosing as well as in loading and unloading applications. Approvals for service in custody transfer (fiscal metering) applications are also available.