All Metall Variable Area Flow Meter BGK
For liquids and gases
Measuring range:
0.1 - 1 ... 20 - 200 l/h water
5.0 - 50 ... 600 - 6000 Nl/h air
Connection: flange DN10 - 25 or ANSI ½", ¾", 1"
Material: stainless steel
pmax: 40 bar (higher on request)
Temperature range: -40 ... +130°C
Contact: -25 ... +100°C, analogue output: -40 ... +100°C
Accuracy: ±3 % qG = 50 %
Option: contacts, analogue output
Protection: IP65 (EN60529)
Explosion protection: BVS 03 ATEX H/B 113
Datasheet
Operating Instructions
Miscellaneous
Approvals
Function
The fluid flows from bottom to top through the meter tube of the flow meter. The float is lifted until an annular gap between the measuring cone and the float is produced which corresponds to the flow. The forces acting on the float are in equilibrium.
The height of the float resulting from the flow rate is transmitted by the permanent magnet in the float through the magnetic tracking system in a rotation to the pointer axis of the analog indicator unit.
The variable-area flowmeter consists of a stainless steel device with an integrated conical stainless steel measuring tube and a vertically movable float.