Vortex Flow Meter DVE
Multi-parameter
Measuring range:
5.2 - 157 ... 284 - 85371 m³/h liquids
89 - 1463 ... 26915 - 2467081 Nm³/h (20°C, 0 bar rel) air
81 - 938 ... 22435 -1324739 kg/h (0 bar rel) vapour
Connection:
Insert version with screw or flange
for tubes DN80 ... DN600 (3"... 24")
Material: stainless steel
pmax: 100 bar
tmax: 360°C (400°C)
Accuracy:
±1.2 % of reading liquids
±1.5 % of reading gas/vapour
1 (3) analogue outputs, 1(3) contacts, digital display
Option: temperature / pressure sensor
ATEX, IEC Ex
Datasheet
Operating Instructions
Miscellaneous
Approvals
Vortex Sizing
Description
The KOBOLD Vortex Flowmeter DVE utilises three primary sensing elements: a vortex shedding velocity sensor, a RTD temperature sensor and a solid-state pressure transducer to measure the mass flow rate of gases, liquids and steam. Systems that use external process measurements may not provide adequate compensation for the fact that process conditions can change radically between the point of velocity measurement and the point where upstream or downstream pressure and temperature measurements are being made.
Because the DVE multivariable flow meter measures all of these parameters in a single location, it delivers a more accurate process measurement. Integrating multivariable output capability with a single line penetration also simplifies system complexity and helps reduce initial equipment cost, installation cost and maintenance costs.