Variable Area Flow Meter / Switch - All Metal - Low Volume KDS
Measuring range:
0.1 - 1 l/h ... 20 - 200 l/h water
3.0 - 30 Nl/h ... 600 - 6000 Nl/h air
Connection: ¼" NPT
Material: stainless steel
pmax: 40 bar (63 bar), up to 420 bar on request
tmax: +130°C
Contact: -25 ... +100°C, analogue output: -40 ... +100°C
Accuracy: ±3 % of full scale
Option: contacts, analogue output, up / downstream pressure regulator
Datasheet
Operating Instructions
Miscellaneous
Approvals
Function
The fluid flows from bottom to top through the meter tube of the flowmeter. The float is lifted until an annular gap between the measuring cone and the float is produced which corresponds to the flow. The forces acting on the float are in equilibrium.
The height of the float resulting from the flow rate is transmitted by the permanent magnet in the float through the magnetic tracking system in a rotation to the pointer axis of the analog indicator unit.
The variable-area flowmeter consists of a stainless steel device with an integrated conical stainless steel measuring tube and a vertically movable float. The valve for setting the flow rate is built-in (only KDS-K/C).