zed-d-zubehoer.png: Batching electronic ZED-D

Batching electronic ZED-D

Input:
1x pulse: 0.2 - 2000 Hz (5 - 24 VDC)
2x control input: start/stopp, reset function
Output: 1x 0(4) - 20 mA  or  0 - 10 V, 2x changer
tmax: -20 ... +70°C
Power supply: 24 VDC or 90 - 250 VAC
Electrical connection: screw terminal, cable gland M18
Display: LCD, 8-digit (quantity) + 5-digit (dosage), backlight
Sensor supply, menu controlled, password, Teach-in procedure, panel mounting, field housing

Datasheet

application/pdf; charset=binary

zed-gb-accessories

509 KB

Miscellaneous

application/pdf; charset=binary

General Safety Instructions

190 KB

Description

The evaluation unit changes the frequency signal of the pickup into a 3(4)-digit flow reading with adjustable scale (top line of display), and a scalable analogue signal. The dosage is displayed in the bottom line of the display. The unit of measurement can be selected. Included are two relays with floated output changeover contacts for various functions. The relay (S1) can be used to execute the flow monitoring, total volume monitoring, fine dosage or the pump control. When the flow is being continuously monitored, it checks if the freely adjustable limits are exceeded or fallen short of.  

A choice can be made between threshold value and window monitoring. Switching point, hysteresis, window point, and switch-on or switch-off delay can be set as desired. If monitoring of the total volume is selected, a check is made to see if the adjustable quantity limit is exceeded. The dosage relay (S2) switches on when the dosage process starts, and then switches off again, once the dosage has flowed through. The dosage process can be interrupted by using the Start/Stop switch.

By taking a correction quantity into account, it is possible to take any special features or conditions of the system into account. By entering a fine dosage, the bypass valve can be controlled with the relay (S1). A red LED indicates the relay’s switching status. The Analogue output is available as a current output with 0(4)...20 mA or a voltage output with 0...10 V.

The parameter names in the menu can be displayed in either German or English. If used where the fl ow readings change rapidly, the display can be pacified and the analogue reading averaged by switching on some software. If the maximum set flow (exceeded range) is exceeded, it will be shown on the display. The set parameters can be protected against unauthorised alteration using a password function.

 

Other Members of the KOBOLD group

Products by Keyword
KOBOLD Instruments Inc.

1801 Parkway View Drive
15205 Pittsburgh PA
United States of America

Please activate JavaScript

Cookies & Features

This website uses cookies to provide content and features. Details of the technologies used can be found in our privacy policy.

Essential Cookies

Session data such as language selection or spam protection - you can't do without it.

Google Media

Some pages on this website load content from Google Maps and YouTube.

loading
loading