Screw Spindle-Meter OMG, OMH, OMS

Measuring range:
0.1 - 10 l/min ... 50 - 5000 l/min liquid
1 - 1000000 mm²/s viskosity
Accuracy: ±0.1 % of span (1:100), ±0.3 % of span (1:150)
Connection: G ½ ...6 female thread, flange DN15 ... 100
Working conditions
pmax: 420 bar
tmax: 200°C
Output: 1x pulse
Electrical connection: right-angle plug, PTFE-cable,
cable box / 1 m PTFE-cable, PVC-cable
Power supply: 10 ... 30 VDC
Material: ductil iron, stainless steel
Pulsation-free principle of measurement, almost insensitive to viscosity, minimum space requirements,
self-cleaning measuring chambers, choice of installation

OMG with ADI-1
magnify

OMG with ADI-1

OMG with ZED
magnify

OMG with ZED

OMH with ADI-1
magnify

OMH with ADI-1

OMH with ZED
magnify

OMH with ZED

OMS with ADI-1
magnify

OMS with ADI-1

OMS with ZED
magnify

OMS with ZED

Datasheet

application/pdf; charset=binary

om-gb-flow

540 KB

Operating Instructions

application/pdf; charset=binary

OMx sensor - Operating Instructions

878 KB
application/pdf; charset=binary

OMH - Operating Instructions

1,4 MB
application/pdf; charset=binary

OMG - Operating Instructions

643 KB
application/pdf; charset=binary

OMS - Operating Instructions

824 KB
application/pdf; charset=binary

ADI-1F - Operating Instructions

1,7 MB

Miscellaneous

application/pdf; charset=binary

General Safety Instructions

190 KB

Description

The KOBOLD screw-type volumetric flowmeter based on the principle of positive displacement was developed in response to the need to measure and control viscous media.
It was specially designed to measure viscous media with non-abrasive properties. Variations in viscosity in the range 1 to 5000 mm2/s have no effect on measurement results within the measuring accuracy.
The KOBOLD screw-type volumetric flowmeter satisfies the stringent demands for greater accuracy, reliability and economic efficiency. Two spindles with cycloidal profiles form the basis of the screw-type volumetric flowmeter.
Spindles manufactured with extreme precision are supported at each end with a ball bearing.
The axially forced measuring medium causes the spindles to rotate uniformly.
The rotary motion is picked off with sensors and converted to a frequency signal. An exact measurement of the delivered flow volume is obtained with the volumetrically defined measuring chambers.
Combined with downstream evaluation electronics, the KOBOLD screw-type volumetric flowmeter becomes a flexible measurement and control system for viscous media.

Other Members of the KOBOLD group

Products by Keyword
KOBOLD Instruments Inc.

1801 Parkway View Drive
15205 Pittsburgh PA
United States of America

Please activate JavaScript

Cookies & Features

This website uses cookies to provide content and features. Details of the technologies used can be found in our privacy policy.

Essential Cookies

Session data such as language selection or spam protection - you can't do without it.

Google Media

Some pages on this website load content from Google Maps and YouTube.

loading
loading