zed-k-zubehoer.png: Electronic for Measuring and Monitoring ZED-K

Electronic for Measuring and Monitoring ZED-K

Input:
1x pulse: 0.2 - 2000 Hz (5 - 24 VDC)
2x control input: start/stopp, reset function
Output: 1x 0(4) - 20 mA  or  0 - 10 V, 2x changer
tmax: -20 ... +70°C
Power supply: 24 VDC or 90 - 250 VAC
Electrical connection: screw terminal, cable gland M18
Display: LCD, 8-digit (quantity) + 5-digit (dosage), backlight
Sensor supply, menu controlled, password,
Teach-in procedure, panel mounting, field housing, Min/Max-memory

Datasheet

application/pdf; charset=binary

zed-gb-accessories

509 KB

Miscellaneous

application/pdf; charset=binary

General Safety Instructions

190 KB

Description

The evaluation unit changes the frequency signal of the pickup into a 3(4)-digit flow reading with selectable measuring unit and into a scalable analogue signal. The two threshold value relays with floating output changeover contacts continuously monitor the flow to check if the freely settable limits are exceeded or fallen short of. Here, it is possible to select either threshold value or window monitoring. The switching point, the hysteresis, a window point and the switch on or off delay can be set separately for each relay.

The switching points can also be set directly using the control keys without having to switch over into the menu. A red LED indicates the switching statuses. The bottom line of the display shows a bar graph of the flow readings. The analogue output is available as current output with 0(4)...20 mA or as voltage output with 0...10 V. The parameter names in the menu can be shown in German or English. If used where the flow readings change rapidly, the display can be pacified and the analogue reading averaged by switching on some software.

A MIN/MAX reading memory determines the extreme values of the flow. The display of the readings and the resetting are achieved by using the keys, without having to change into the menu. Resetting by using the keys can also be blocked. If the maximum set flow (exceeded range) is exceeded, it will be shown on the display. The set parameters can be protected against unauthorised alteration by using a password function.

 

Other Members of the KOBOLD group

Products by Keyword
KOBOLD Instruments Inc.

1801 Parkway View Drive
15205 Pittsburgh PA
United States of America

Please activate JavaScript

Cookies & Features

This website uses cookies to provide content and features. Details of the technologies used can be found in our privacy policy.

Essential Cookies

Session data such as language selection or spam protection - you can't do without it.

Google Media

Some pages on this website load content from Google Maps and YouTube.

loading
loading