Medidor y Totalizador de caudal Másico TMU

Wide measuring span

Measuring range:
0 - 60 kg/h ... 0 - 2200 t/h water (TMU-...AC, TMU/UMC-4)
0 - 600 kg/h ... 0 - 2200 t/h water (TMU/UMC-3)
Connection: flange DN10 - DN400, ANSI ½ ... 16"
JIS, NPT, special according customers specification
Material:
stainless steel (1.4571 or 1.4404), Hastelloy® C-22
pmax: PN40 (higher on request)
Temperature range: -40 ... +260°C
Accuracy:
±0.1 (0.15) % of reading ±zero point-stability liquids
±0.5 % of reading ±zero point-stability gases
±0,005 g/cm³ with calibration density (TMU/UMC-4)
±0,002(0,001) g/cm³ with special calibration density (TMU/UMC-4)
±0,2% of reading ±zero-point-stability volume (TMU/UMC-4)
Transmitter:
Analog / pulse output, digital display, Hart®, Profibus® PA, ATEX, FM, FMC, NEPSI

TMU
magnify

TMU

TMU High Flow
magnify

TMU High Flow

Hoja de datos

application/pdf; charset=binary

tmu-gb-flow

462 KB

Instrucciones de operación

application/pdf; charset=binary

UMC3 Ex - Operating Instructions

2,2 MB
application/pdf; charset=binary

TMU UMC4 - Operating Instructions

4,2 MB
application/pdf; charset=binary

UMC4 Ex - Operating Instructions

2,4 MB
application/pdf; charset=binary

UMC3-FF - Operating Instructions

577 KB
application/pdf; charset=binary

TMU UMC3 - Operating Instructions

4,2 MB
application/pdf; charset=binary

TM, TMU, TM-SH - Operating Instruction

1,5 MB

Certificaciones / Aprobaciones

application/pdf; charset=binary

DMT01ATEXE149X

II 1/2G Ex ia IIC T6-T2 Ga/Gb
II 1/2G Ex ia IIC T5/T4 Ga/Gb

4,1 MB
application/pdf; charset=binary

IECExBVS11.0084X

Ex ia IIC T6 - T2 Ga/Gb

1,4 MB
application/pdf; charset=binary

3023373

FM Approval

43 KB
application/pdf; charset=binary

3023373C

FM Approval

43 KB
application/pdf; charset=binary

GYJ12.1038X

NEPSI
Ex ia IIC T6~T2 Ga/Gb

360 KB
application/pdf; charset=binary

BVS05ATEXE021X (UMC-3)

II (1)2G Ex d[ia] IIB/IIC T6-T3
II (1)2G Ex d e[ia] IIB/IIC T6-T3
II 2D Ex tD A21 IP6x T80°C-T150°C

465 KB
application/pdf; charset=binary

IECExBVS11.0094X (UMC-3)

Ex d[ia Ga] IIB/IIC T6-T3 Gb
Ex ia IIC T6 Ga

4,8 MB
application/pdf; charset=binary

GYJ12.1040X (UMC-3)

NEPSI
Ex D[ia Ga] IIB/IIC T6/T5 Gb
Ex de[ia Ga] IIB/IIC T6/T5 Gb

441 KB
application/pdf; charset=binary

BVS10ATEXE110X (UMC-4)

II (1)2G Ex d[ia Ga] IIC T4-T3 Gb

868 KB
application/pdf; charset=binary

IECExBVS11.0088X (UMC-4)

Ex d[ia Ga] IIC T4-T3 Gb

407 KB
application/pdf; charset=binary

TAA00002CD-revision1

204 KB

Descargas

application/zip; charset=binary

Software

Foundation Fieldbus

172 KB
application/zip; charset=binary

Software

Profibus-PA

5 KB

Otros miembros del grupo KOBOLD

Elija los productos según una palabra clave
KOBOLD Instruments Inc.

1801 Parkway View Drive
15205 Pittsburgh PA
Estados Unidos

Por favor, active JavaScript

Cookies & Features

Este sitio web utiliza cookies para ofrecer contenidos y funciones. Los detalles de las tecnologías utilizadas pueden encontrarse en nuestra política de privacidad.

Cookies esenciales

Los datos de la sesión, como la selección del idioma o la protección contra el spam, no pueden prescindir de ellos.

Google Services

Some pages on this website load content from Google Maps and YouTube.

loading
loading